Although low-resolution endoscopes have relatively low pixels, they have irreplaceable advantages in specific application scenarios, mainly reflected in the following aspects:1. Miniaturization and high adaptability The probe diameter can be as small as 2.8mm or even smaller, and it can reach narro
The choice between side view and direct view of the endoscope camera module for image output mainly depends on your inspection requirements. Direct-view lenses are suitable for large-scale inspections in open Spaces, such as the inner walls of pipes or engine blocks. They offer a wide field of view
The compatibility of endoscope camera modules with ordinary endoscope systems (e.g., Olympus or Storz) depends on several technical factors:Physical Interface CompatibilityMost endoscope camera modules are designed with standardized C-mount or other industry-standard interfaces that allow integrati
Why are high-resolution industrial endoscope camera modules more prone to overheating?At present, when industrial endoscopes are upgraded to 4K/60fps, the power consumption of the chip surges. For instance, the power consumption of the IMX415 sensor reaches 1.2W, but the mirror tube with a diameter
Currently, the endoscope camera module can be equipped with both LED beads and fiber supplementary lighting . This composite design combines the advantages of both light sources to adapt to more complex inspection environments and improve imaging quality. The following are the key bases and techni
The integration of LED beads in the endoscope camera module is mainly based on three core requirements: space efficiency, optical control, and environmental adaptability. The specific advantages and technical principles are as follows:I. Optimization of Space Utilization RateMiniaturized packaging
Disposable endoscope modules are usually treated as medical waste and must strictly follow the following disposal procedures:1. Youdaoplaceholder0 Sealed packaging and sorting Immediately seal it in a dedicated medical waste packaging bag/container after use, mark it as "infectious Waste", and it i
The selection of the diameter of the endoscopic camera module should be comprehensively evaluated based on specific application scenarios, rather than simply pursuing the smallest size. The key considerations are as follows:I. The Core Value and Limitations of Small DiameterAdaptability in confined
In the selection process of endoscope camera modules, how to correctly strike a balance between resolution and clarity?At present, the endoscope camera module is the preferred option for shooting in narrow environments. However, when choosing an endoscope camera module, it is not the case that the h
Whether the internal camera module of the industrial pipeline inspection endoscope needs to be equipped with an infrared LED lamp should be determined through a comprehensive assessment based on the inspection scenario requirements and the characteristics of infrared technology.
In the current industrial inspection and clinical medical fields, the application of endoscopes has become very widespread. However, there are significant differences in how these two fields should choose the appropriate endoscopes. The following is a comprehensive analysis of the selection of endos
The importance of advanced tools in modern maintenance and repair work cannot be overstated, particularly when it comes to inspecting hard-to-reach or hidden systems.
This professional-grade 3.9mm endoscope camera delivers 720P resolution at 60fps, paired with multi-coated lenses and high-brightness LEDs for crisp, low-noise imaging in challenging environments. Its DSP processor enables real-time noise reduction and color optimization, while electronic stabilizat
This innovative endoscope camera module combines a specialized BF2013 CMOS sensor with six integrated LED beads, delivering sharp 653×493 resolution video at 30 FPS even in low-light conditions. Designed for extreme environments, its 2mm-diameter probe and 60mm length allow access to tightly confine
This miniature endoscope camera is equipped with the OV97342 chip, featuring both high precision and miniaturization. Its 1-megapixel sensor supports a high-definition resolution of 1280×720. Combined with an 88° wide field of view, it can clearly capture details within a depth range of 10-40mm, making it suitable for operations in narrow Spaces.
The 3.5mm industrial-grade endoscope module is designed for complex mechanical inspection, equipped with OV9734 sensor output 1280×720 HD image quality, and smooth 30FPS transmission via USB interface. Its six ring leds provide shadowless lighting with an 88° wide-angle field of view, which can clea
The 3.5mm industrial-grade endoscope module is designed for complex mechanical inspection, equipped with OV9734 sensor output 1280×720 HD image quality, and smooth 30FPS transmission via USB interface. Its six ring leds provide shadowless lighting with an 88° wide-angle field of view, which can clea
In modern plumbing and drainage maintenance, efficiency, precision, and minimal invasiveness are essential.
In today's fast-paced world, real-time mobile inspection has become an invaluable tool across various industries.
How Oral Endoscope Cameras Improve Dental Health MonitoringAdvancements in medical technology have revolutionized healthcare in many ways, and dental health is no exception.
Availability: | |
---|---|
Quantity: | |
SF-C0310USB-D3.9-PLUS-D9
SINCEREFIRST
This 3.9mm USB medical endoscope camera module integrates VGA sensor and MINI USB2.0 interface, designed for minimally invasive surgery and endoscopy. Its 1.074mm ultra-short focal length and F3.58 aperture achieve accurate imaging in the ultra-wide focusing range of 20mm-80mm, adapting to the observation needs of different depth lesions. The 90° diagonal field of view covers a wider cavity area, combined with < -5.5% TV distortion control to ensure low image edge distortion and facilitate accurate diagnosis. Built-in LED lights provide uniform lighting, eliminate dark corner effects, with USB2.0 plug and play function, fast access to surgical monitoring equipment. With an ultra-fine diameter of 3.9mm, this module supports the integration of minimally invasive surgical instruments, taking into account high resolution and flexible operation, and is widely used in abdominal examination, ENT diagnosis and treatment, and minimally invasive intervention of urinary system, providing reliable support for medical visualization. It is also used in motor vehicle detection, engine fault detection and so on. |
Features ◢
1. Ultra HD detail capture: VGA sensor +90° wide Angle, covering a larger detection area, edge distortion < -5.5%, to ensure measurement accuracy.
2. Flexible depth adaptation: 20mm-80mm focus range +F3.58 large aperture, suitable for different depth lesions or mechanical structure observation.
3. Dark environment optimization: Built-in LED lights complement the light, eliminate dark corners, and improve the imaging quality in the cavity/small space.
Application Of Endoscope Camera Module ◢
1. Engine inspection: Go deep into the cylinder, crankcase and other hidden parts to check carbon deposits, cracks or foreign bodies.
2. Endoscopic diagnosis: screening of internal lesions of digestive tract, respiratory tract and other lumens.
3. Minimally invasive surgery: abdominal/ENT/urinary system endoscopic integration, supporting 3.9mm instrument channel to achieve high-definition lesion observation.
Product Details ◢
Keywords | 3.9mm USB Endoscope Camera Module |
Sensor | VGA |
LED | 4pcs LED |
Module Size | 3.9mm dia |
Focusing Range | 20mm-80mm |
Focal Length | 1.074mm |
FOV(D) | 90° |
TV Distortion | <-5.5% |
Output Format | YUV&MJPG |
F Number | 3.58 |
Output | USB2.0 UVC |
Features | Mini Endoscope Camera |
FAQ ◢
1. What is the difference between medical and industrial endoscope modules?
The medical module emphasizes biocompatibility, sterilization and high image quality, and needs to comply with FDA/CE certification; Industrial modules focus on durability (such as corrosion protection), wide temperature operation (-20°C to 70°C), and special light sources.
2. Why do Otolaryngology departments need ultra-small diameter modules?
With narrow ear/nasal space, modules with a diameter of less than 3mm can reduce patient discomfort while maintaining high resolution (e.g., ≥300 line pairs /mm) to identify small lesions.
3. How to choose the module suitable for car maintenance?
It is necessary to have an oil-proof lens, adjustable focal length (such as 10-100mm), LED strong light, some with magnetic probes or 360° rotating head to check the engine dead Angle.
This 3.9mm USB medical endoscope camera module integrates VGA sensor and MINI USB2.0 interface, designed for minimally invasive surgery and endoscopy. Its 1.074mm ultra-short focal length and F3.58 aperture achieve accurate imaging in the ultra-wide focusing range of 20mm-80mm, adapting to the observation needs of different depth lesions. The 90° diagonal field of view covers a wider cavity area, combined with < -5.5% TV distortion control to ensure low image edge distortion and facilitate accurate diagnosis. Built-in LED lights provide uniform lighting, eliminate dark corner effects, with USB2.0 plug and play function, fast access to surgical monitoring equipment. With an ultra-fine diameter of 3.9mm, this module supports the integration of minimally invasive surgical instruments, taking into account high resolution and flexible operation, and is widely used in abdominal examination, ENT diagnosis and treatment, and minimally invasive intervention of urinary system, providing reliable support for medical visualization. It is also used in motor vehicle detection, engine fault detection and so on. |
Features ◢
1. Ultra HD detail capture: VGA sensor +90° wide Angle, covering a larger detection area, edge distortion < -5.5%, to ensure measurement accuracy.
2. Flexible depth adaptation: 20mm-80mm focus range +F3.58 large aperture, suitable for different depth lesions or mechanical structure observation.
3. Dark environment optimization: Built-in LED lights complement the light, eliminate dark corners, and improve the imaging quality in the cavity/small space.
Application Of Endoscope Camera Module ◢
1. Engine inspection: Go deep into the cylinder, crankcase and other hidden parts to check carbon deposits, cracks or foreign bodies.
2. Endoscopic diagnosis: screening of internal lesions of digestive tract, respiratory tract and other lumens.
3. Minimally invasive surgery: abdominal/ENT/urinary system endoscopic integration, supporting 3.9mm instrument channel to achieve high-definition lesion observation.
Product Details ◢
Keywords | 3.9mm USB Endoscope Camera Module |
Sensor | VGA |
LED | 4pcs LED |
Module Size | 3.9mm dia |
Focusing Range | 20mm-80mm |
Focal Length | 1.074mm |
FOV(D) | 90° |
TV Distortion | <-5.5% |
Output Format | YUV&MJPG |
F Number | 3.58 |
Output | USB2.0 UVC |
Features | Mini Endoscope Camera |
FAQ ◢
1. What is the difference between medical and industrial endoscope modules?
The medical module emphasizes biocompatibility, sterilization and high image quality, and needs to comply with FDA/CE certification; Industrial modules focus on durability (such as corrosion protection), wide temperature operation (-20°C to 70°C), and special light sources.
2. Why do Otolaryngology departments need ultra-small diameter modules?
With narrow ear/nasal space, modules with a diameter of less than 3mm can reduce patient discomfort while maintaining high resolution (e.g., ≥300 line pairs /mm) to identify small lesions.
3. How to choose the module suitable for car maintenance?
It is necessary to have an oil-proof lens, adjustable focal length (such as 10-100mm), LED strong light, some with magnetic probes or 360° rotating head to check the engine dead Angle.